SYSTEM
OVERVIEW |
|
System overview:
|
Line interactive tower UPS protects
internetworking and
telecommunications equipment from
blackouts, brownouts, overvoltages,
surges and line noise. Maintains AC
output during blackouts and
continuously corrects brownouts and
overvoltages from 75 to 147 volts
back to normal 120V levels. Supports
enhanced monitoring of UPS and line
power conditions via USB serial
port, included PowerAlert UPS
monitoring software and cabling.
|
|
Voltage compatibility:
|
120V AC
|
|
Frequency compatibility:
|
60Hz
|
|
OUTPUT |
|
Output volt amp capacity
(VA):
|
700
|
|
Output watt capacity
(watts):
|
450
|
|
Output nominal voltage:
|
120V AC
|
|
Output voltage regulation:
|
LINE MODE: Sine wave line voltage
120V (-18% / +8%)
|
|
Output frequency regulation:
|
LINE MODE: Passes line frequency of
60Hz +/-10%
|
|
Outlet quantity / type:
|
6 NEMA 5-15R
|
|
INPUT |
|
Maximum input amps:
|
4.4A / 490 watts
|
|
Input connection type:
|
NEMA 5-15P
|
|
Input cord length:
|
6 ft., 16 gauge
|
|
Recommended electrical
service:
|
15A 120V
|
|
BATTERY |
|
Full load runtime:
|
6 minutes (700VA)
|
|
Half load runtime:
|
20 minutes (350VA)
|
|
DC system voltage:
|
12 VDC
|
|
Typical battery lifespan:
|
3-6 years, depending on usage
|
|
Battery recharge rate:
|
2-4 hours to 90%
|
|
Replacement Battery
Cartridge:
|
RBC52 (quantity 2)
|
|
VOLTAGE
REGULATION |
|
Voltage regulation
description:
|
Automatic Voltage Regulation (AVR)
circuits maintain clean, regulated
computer-grade 120V nominal output,
without using battery power, during
brownouts to 75V and overvoltages to
147V
|
|
Overvoltage correction:
|
Input voltages between 128 and 147V
AC are reduced by 12%
|
|
Direct pass through:
|
Input voltages between 108 and 127V
AC are passed on to connected
equipment unchanged
|
|
Brownout correction:
|
Input voltages between 93 and 107V
AC are boosted by 14%
|
|
Severe brownout correction:
|
Input voltages between 75 and 92V AC
are boosted by 30%
|
|
LEDS
ALARMS & SWITCHES |
|
Front panel LEDs:
|
Includes 5 front panel LEDs to
indicate BATTERY CHARGE LEVEL, AC
LINE POWER STATUS, VOLTAGE
REGULATION STATUS, UPS LOAD LEVEL
and BATTERY LOW / REPLACE
information
|
|
Alarms:
|
Audible alarm with 15 second delay
sounds to indicate loss of utility
power. Alarm can be silenced by
pressing front panel alarm cancel
button. Once silenced, alarm will
re-sound when approximately 2
minutes runtime remain.
|
|
Switches:
|
Includes 2 front panel switches—one
main on/off power switch and one
dual function "alarm cancel" / "self
test" button
|
|
SURGE /
NOISE SUPPRESSION |
|
AC surge suppression:
|
480 joules
|
|
AC suppression response
time:
|
Instantaneous
|
|
EMI / RFI AC noise
suppression:
|
Yes
|
|
PHYSICAL |
|
Shipping weight (lbs):
|
24
|
|
Shipping weight (kg):
|
10.9
|
|
Unit weight (lbs):
|
22
|
|
Unit weight (kg):
|
10.0
|
|
Unit Dimensions (HWD/in):
|
11.75 x 7.25 x 7.5
|
|
Unit Dimensions (HWD/cm):
|
29.8 x 18.4 x 19.1
|
|
Shipping Dimensions
(HWD/in):
|
15.5 x 11 x 11.25
|
|
Shipping Dimensions
(HWD/cm):
|
39.4 x 28 x 28.6
|
|
Material of construction:
|
PVC
|
|
Form factors supported:
|
Tower
|
|
Cooling method:
|
Convection
|
|
Battery Access:
|
Battery access door allows user
replacement of UPS batteries
|
|
ENVIRONMENTAL |
|
Operating Temperature:
|
+32 to +104 degrees Fahrenheit
|
|
Storage Temperature:
|
+5 to +122 degrees Fahrenheit
|
|
Relative Humidity:
|
0 to 95%, non-condensing
|
|
COMMUNICATIONS |
|
Network monitoring port:
|
Built-in USB port supports on
battery, low battery, power
restored, AC line voltage, DC
battery voltage, load percentage,
battery charge current, battery
capacity, internal UPS temperature
and line frequency status messaging.
Interface supports timed inverter
shutoff after unattended shutdown,
activate self-test and 10 second
reboot of connected equipment.
Supports reboot of all connected
devices at once via software
interface. Compatible with Tripp
Lite's PowerAlert software.
|
|
Software and cabling
included:
|
Includes PowerAlert UPS monitoring
and auto-shutdown software and
cabling
|
|
WatchDog compatibility:
|
Yes, compatible with Tripp Lite's
Watchdog system service to restore
operation to locked equipment
through soft reboot of application /
OS or hard power off/on reboot of
connected equipment - ideal for
unattended kiosk applications
|
|
LINE /
BATTERY TRANSFER |
|
Transfer time from line
power to battery mode:
|
2-4 milliseconds
|
|
Low voltage transfer to
battery power:
|
Switches to battery power as line
voltage decreases to 75 volts or
less. Resets back to line power mode
as line voltage increases to 79V or
higher.
|
|
High voltage transfer to
battery power:
|
Switches to battery power as line
voltage increases to 147 volts or
higher. Resets to line power mode as
line voltage decreases to 143V or
less.
|
|
CERTIFICATIONS |
|
Certifications:
|
UL1778 (USA), cUL (Canada), Class A
(Emissions), NOM (Mexico)
|
|
WARRANTY |
|
Optional coverage:
|
3-5 year warranties, plus next day
and on-site warranty coverage
available for select opportunities.
Contact Tripp Lite for additional
information.
|
|
Product warranty:
|
2 year product warranty
|
|
Connected equipment
insurance (USA and Canada Only):
|
$250,000 connected equipment
insurance (USA / Canada only)
|
|
SPECIAL
FEATURES |
|
Cold Start:
|
Yes, inverter can be "cold started"
to enable temporary AC output during
a power failure
|
|
Appearance:
|
Attractive black tower UPS
|