SYSTEM
OVERVIEW |
|
System overview:
|
Line interactive tower UPS system
protects PCs, network workstations
and other sensitive electronics from
blackouts, brownouts, overvoltages
and line noise. Maintains AC output
during blackouts and continuously
corrects brownouts and overvoltages
from 75 to 147 volts back to normal
120V levels. Includes USB monitoring
port with cabling, TEL / DSL surge
suppression, surge only outlets and
LED indicators. PowerAlert software
available free via download.
|
|
Voltage compatibility:
|
120VAC
|
|
Frequency compatibility:
|
60Hz
|
|
OUTPUT |
|
Output volt amp capacity
(VA):
|
500
|
|
Output watt capacity
(watts):
|
300
|
|
Output nominal voltage:
|
120VAC
|
|
Output voltage regulation:
|
LINE MODE: Sine wave line voltage
120V (-18% / +8%), BATTERY MODE: PWM
sine wave output 120V +/-5%
|
|
Output frequency regulation:
|
LINE MODE: Passes line frequency of
60Hz +/-10% BATTERY MODE: Inverter
output regulated to 60Hz +/-0.5Hz
|
|
Outlet quantity / type:
|
6 NEMA 5-15R
|
|
INPUT |
|
Maximum input amps:
|
10A / 1200 watts
|
|
Input connection type:
|
NEMA 5-15P
|
|
Input cord length:
|
6 ft., 16 gauge
|
|
Recommended electrical
service:
|
15A 120V
|
|
BATTERY |
|
Full load runtime:
|
5 minutes (500VA)
|
|
Half load runtime:
|
17 minutes (250VA)
|
|
DC system voltage:
|
12 VDC
|
|
Typical battery lifespan:
|
3-6 years, depending on usage
|
|
Battery recharge rate:
|
2-4 hours to 90%
|
|
Replacement Battery
Cartridge:
|
RBC51
|
|
VOLTAGE
REGULATION |
|
Voltage regulation
description:
|
Automatic Voltage Regulation (AVR)
circuits maintain clean, regulated
computer-grade 120V nominal output,
without using battery power, during
brownouts to 75V and overvoltages to
147V
|
|
Overvoltage correction:
|
Input voltages between 128 and 147V
AC are reduced by 12%
|
|
Direct pass through:
|
Input voltages between 108 and 127V
AC are passed on to connected
equipment unchanged
|
|
Brownout correction:
|
Input voltages between 93 and 107V
AC are boosted by 14%
|
|
Severe brownout correction:
|
Input voltages between 75 and 92V AC
are boosted by 30%
|
|
LEDS
ALARMS & SWITCHES |
|
Front panel LEDs:
|
4 front panel LEDs indicate line
power status, battery power status,
battery low/replace status and
overload
|
|
Alarms:
|
Audible alarm with 15 second delay
sounds to indicate loss of utility
power. Alarm can be silenced by
pressing front panel alarm cancel
button. Once silenced, alarm will
re-sound when approximately 2
minutes runtime remain.
|
|
Switches:
|
Includes 2 front panel switches —
one main on/off power switch and one
dual function "alarm cancel" / "self
test" button
|
|
SURGE /
NOISE SUPPRESSION |
|
AC surge suppression:
|
480 joules
|
|
AC suppression response
time:
|
Instantaneous
|
|
Dataline suppression:
|
Tel/DSL
|
|
EMI / RFI AC noise
suppression:
|
Yes
|
|
PHYSICAL |
|
Shipping weight (lbs):
|
15.4
|
|
Shipping weight (kg):
|
7.0
|
|
Unit weight (lbs):
|
14
|
|
Unit weight (kg):
|
6.4
|
|
Unit Dimensions (HWD/in):
|
8.5 x 5 x 6.5
|
|
Unit Dimensions (HWD/cm):
|
21.6 x 12.7 x 16.5
|
|
Shipping Dimensions
(HWD/in):
|
12 x 8.25 x 9.25
|
|
Shipping Dimensions
(HWD/cm):
|
30.5 x 21 x 23.5
|
|
Material of construction:
|
PVC
|
|
Form factors supported:
|
Tower
|
|
Cooling method:
|
Convection
|
|
Battery Access:
|
Battery access door allows user
replacement of UPS batteries.
|
|
ENVIRONMENTAL |
|
Operating Temperature:
|
+32 to +104 degrees Fahrenheit
0 to +40 degrees Celsius
|
|
Storage Temperature:
|
+5 to +122 degrees Fahrenheit
-15 to +50 degrees Celsius
|
|
Relative Humidity:
|
0 to 95%, non-condensing
|
|
Line mode BTU/hr. (Max.):
|
26.2
|
|
Battery mode BTU/hr. (Max.):
|
88.7
|
|
COMMUNICATIONS |
|
Network monitoring port:
|
USB
|
|
Software and cabling
included:
|
USB cabling included, PowerAlert
software available for free download
at www.tripplite.com
|
|
WatchDog compatibility:
|
Yes, compatible with Tripp Lite's
Watchdog system service to restore
operation to locked equipment
through soft reboot of application /
OS or hard power off/on reboot of
connected equipment - ideal for
unattended kiosk applications
|
|
LINE /
BATTERY TRANSFER |
|
Transfer time from line
power to battery mode:
|
2-4 milliseconds
|
|
Low voltage transfer to
battery power:
|
Switches to battery power as line
voltage decreases to 75 volts or
less. Resets back to line power mode
as line voltage increases to 79V or
higher.
|
|
High voltage transfer to
battery power:
|
Switches to battery power as line
voltage increases to 147 volts or
higher. Resets back to line power
mode as line voltage decreases to
143V or less.
|
|
CERTIFICATIONS |
|
Certifications:
|
Tested to UL1778 (USA), Tested to
CSA (Canada), Class B (emissions),
NOM (Mexico), FCC Part 68 / Industry
Canada (telecommunications)
|
|
WARRANTY |
|
Optional coverage:
|
3-5 year warranties, plus next day
and on-site warranty coverage
available. Contact Tripp Lite for
additional information.
|
|
Product warranty:
|
2 year product warranty
|
|
Connected equipment
insurance (USA and Canada Only):
|
$200,000 connected equipment
insurance (USA and Canada only)
|
|
SPECIAL
FEATURES |
|
Cold Start:
|
Yes, inverter can be "cold started"
to enable temporary AC output during
a power failure
|
|
Appearance:
|
Attractive gray tower UPS
|