 Tripp Lite Smart Online 1000 Expandable Tower UPS System SU1000XL
Availability: Usually ships the same business day.Tripp Lite Smart Online 1000VA Expandable Tower UPS System SU1000XL SU1000XL $471.83
 Model:
 Qty.:

New Page 2
DESCRIPTION Tripp Lite's Smart Online SU1000XL on-line, double conversion UPS protects critical server, networking or telecommunications equipment from blackouts, brownouts, voltage fluctuations and surges in an attractive all-black upright tower. Large capacity 1kVA / 800 watt UPS continuously converts incoming AC to DC, then back to perfect sine wave AC output at 120V AC (+/-2%). Removes harmonic distortion, fast electrical impulses, frequency fluctuations and other hard-to-solve power problems not addressed by other UPS systems. True sine wave output and zero transfer time offers guaranteed compatibility with all equipment types. Includes 6 UPS supported outlets arranged in two individually switchable load banks that can be independently controlled via a software interface to selectively reboot remote equipment, or automatically shed less critical loads to extend battery runtime for the most critical equipment. Battery support can be extended with the addition of multiple external battery packs (part# BP36V13). Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port for unattended shutdown, remote control and monitoring of UPS system and power data. Includes Tripp Lite's PowerAlert UPS Power Management Software. Compatible with Tripp Lite's Watchdog Service Monitoring/Rebooting Software.
KEY BUYING POINTS True on-line, double conversion UPS provides a constant, pure sine wave AC output
Maintains continuous operation through blackouts, brownouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, electrical impulses, frequency variations and other hard to solve power problems
Accepts input voltages between 80 and 138 (65 to 138 at loads under 70%), regulating output to 120V AC +/-2%
1000VA / 800 watt output capacity with 6 total outlets (6 NEMA5-15R)
Two built-in individually switchable load banks can be controlled via software interface to selectively reboot remote equipment or automatically shed less critical loads to extend battery runtime for the most critical equipment (2 banks of 3 outlets)
Standard internal battery set provides 18 minutes runtime at half load
Expandable runtime with multiple external battery packs (part# BP36V13)
Attractive all-black upright tower format
DB9 serial network interface supports RS-232 and contact closure messaging
Slot for optional SNMP/web card (part# SNMPWEBCARD)
Included PowerAlert UPS Power Management Software and cabling provides monitoring of in-depth site power conditions, full UPS status and fault warnings, output load level and load bank power control
Compatible with Tripp Lite's WatchDog Service Monitoring/Rebooting Software (part# WATCHDOGSW)
Fault tolerant auto-bypass maintians continuous utility output to connected equipment, even in cases where the UPS is overloaded or suffers an internal failure that requires service
Diagnostic LEDs
$250,000 Ultimate Lifetime connected equipment insurance (USA & Canada only)
2 year manufacturer's product warranty
TYPICAL APPLICATIONS Ideal for protection of critical 120V servers, networking equipment and sensitive electronics. Common applications include corporate or departmental servers, workstations, hubs, routers, bridges, CAD/CAM workstations, concentrators, IP telephony and traditional PBX switching systems.
OPTIONS & ACCESSORIES External battery pack: BP36V13
SNMP accessories: SNMPWEBCARD, ENVIROSENSE
Dataline protectors: DNET1, DTEL2, DCATV
Circuit Tester: CT120
Power distribution: PDU1215, PS7224
Extended warranties: 3 Year WEXT3-500-1500, 5 Year WEXT5-500-1500
PACKAGE INCLUDES SU1000XL Online Double-Conversion UPS System
PowerAlert Software and cabling
Instruction manual with warranty information
New Page 3
|
SYSTEM
OVERVIEW |
|
System overview:
|
Online, double conversion tower UPS
system continuously maintains
near-perfect output power for
critical internetworking and
telecommunications equipment.
Completely regenerates input power
into perfectly regulated sine wave
output free of harmonic distortion,
fast electrical impulses and
frequency fluctuations. Maintains
output within 2% of 120V during
brownouts as low as 65V and
overvoltages to 138V. Supports
enhanced monitoring of UPS and line
power conditions via DB9 serial
port, included PowerAlert monitoring
software and complete cabling.
Includes slot for SNMPWEBCARD and 2
individually controllable output
load banks. Runtime is expandable
with BP36V13 battery packs.
|
|
Voltage compatibility:
|
120V AC
|
|
Frequency compatibility:
|
50/60 Hz compatible
|
|
OUTPUT |
|
Output volt amp capacity
(VA):
|
1000
|
|
Output watt capacity
(watts):
|
800
|
|
Output nominal voltage:
|
120V AC
|
|
Output voltage regulation:
|
Maintains full-time sine wave output
within 2% of 120V, less than 5%
total harmonic distortion
|
|
Output frequency regulation:
|
Regulates line frequency to 50/60Hz
+/- 0.05Hz
|
|
Outlet quantity / type:
|
6 NEMA 5-15R
|
|
Customized load management
receptacles:
|
2 individually controllable banks of
3 outlets support automated load
shedding and remote reboot on demand
of locked network devices.
Configurable via PowerAlert software
to automatically switch off optional
loads, like monitors, to increase
available runtime for servers and
other critical devices.
|
|
Overload protection:
|
Via 15A input breaker
|
|
INPUT |
|
Maximum input amps:
|
8.6A
|
|
Input connection type:
|
NEMA 5-15P
|
|
Input cord length:
|
6 ft.
|
|
Recommended electrical
service:
|
15A 120V
|
|
BATTERY |
|
Full load runtime:
|
6 min - internal batteries / 30 min
with 1 BP36V13 battery pack (1000VA)
|
|
Half load runtime:
|
18 min - internal batteries / 70 min
with 1 BP36V13 battery pack (500VA)
|
|
Expandable battery runtime:
|
3 built-in 12V 7AH batteries
|
|
DC system voltage:
|
36VDC
|
|
Typical battery lifespan:
|
3-6 years, depending on usage
|
|
Battery recharge rate:
|
4-6 hours to 90%
|
|
VOLTAGE
REGULATION |
|
Voltage regulation
description:
|
On-line, double-conversion power
conditioning maintains output within
2% of 120 volts at all times
|
|
Overvoltage correction:
|
Maintains output of 120V +/-2%
during overvoltages to 138VAC
|
|
Brownout correction:
|
Maintains output of 120V +/-2%
during undervoltages to 80VAC
|
|
Severe brownout correction:
|
Maintains output of 120V +/-2%
during undervoltages to 65VAC
(during load conditions of 70% or
less)
|
|
LEDS
ALARMS & SWITCHES |
|
Front panel LEDs:
|
14 STATUS LEDs offer LINE POWER,
ONLINE, BYPASS, ON BATTERY,
OVERLOAD, BATTERY LOW, REPLACE
BATTERY and FAULT status
information. Also includes 4 LED
meters for LOAD LEVEL / BATTERY
LEVEL display (Battery level readout
requires pressing "test" key)
|
|
Alarms:
|
Multi-function audible alarm offers
notification of UPS start, backup
operation, low battery warning,
overload, UPS fault and remote
shutdown
|
|
Switches:
|
Includes main power off/on switch,
plus 1 test switch
|
|
SURGE /
NOISE SUPPRESSION |
|
AC surge suppression:
|
480 joules
|
|
AC suppression response
time:
|
Instantaneous
|
|
EMI / RFI AC noise
suppression:
|
Yes
|
|
PHYSICAL |
|
Shipping weight (lbs):
|
39.6
|
|
Shipping weight (kg):
|
18.0
|
|
Unit weight (lbs):
|
33
|
|
Unit weight (kg):
|
15.0
|
|
Unit Dimensions (HWD/in):
|
9.5 x 5.5 x 14.5
|
|
Unit Dimensions (HWD/cm):
|
24.2 x 14 x 36.8
|
|
Shipping Dimensions
(HWD/in):
|
13 x 9.5 x 20
|
|
Shipping Dimensions
(HWD/cm):
|
33 x 24.1 x 50.6
|
|
Material of construction:
|
Steel
|
|
Form factors supported:
|
Tower
|
|
Cooling method:
|
Fan
|
|
ENVIRONMENTAL |
|
Operating Temperature:
|
+32 to +104 degrees Fahrenheit / 0
to +40 degrees Celsius
|
|
Storage Temperature:
|
+5 to +122 degrees Fahrenheit / -15
to +50 degrees Celsius
|
|
Relative Humidity:
|
0 to 95%, non-condensing
|
|
Line mode BTU/hr. (Max.):
|
442.8
|
|
Battery mode BTU/hr. (Max.):
|
442.8
|
|
COMMUNICATIONS |
|
Network monitoring port:
|
Built-in DB9 port offers both
enhanced RS-232 enable monitoring
data, plus contact closure
monitoring ability
|
|
Software and cabling
included:
|
Yes, includes PowerAlert software
CD-ROM and complete cabling
|
|
SNMP compatibility:
|
Yes, includes slot for optional
SNMPWEBCARD accessory (#SNMPWEBCARD)
|
|
WatchDog compatibility:
|
Yes, compatible with Tripp Lite's
Watchdog system service to restore
operation to locked equipment
through soft reboot of applications
/ OS or hard power off/on reboot of
connected equipment — ideal for
unattended kiosk applications
|
|
LINE /
BATTERY TRANSFER |
|
Transfer time from line
power to battery mode:
|
ZERO — online UPS continuously
converts incoming AC to DC, then
back to AC. When commercial power is
interrupted, UPS maintains
continuous output from battery
reserves with absolutely no
disruption in output AC power.
|
|
Low voltage transfer to
battery power:
|
Maintains continuous operation
during undervoltages as low as 80V
(65V during load conditions of 70%
or less). Below the switchover
point, output is supported from
battery derived AC power.
|
|
High voltage transfer to
battery power:
|
Maintains continuous operation
without using battery power during
overvoltages to 138V. Above this
point, output is supported from
battery derived AC power.
|
|
CERTIFICATIONS |
|
Certifications:
|
Tested to UL1778 (USA), CSA C22.2
No. 107.3 (Canada), Class B
(emissions), NOM (Mexico)
|
|
WARRANTY |
|
Optional coverage:
|
3-5 year warranties, plus next day
and on-site warranty coverage
available for select opportunities.
Contact Tripp Lite for additional
information.
|
|
Product warranty:
|
2 year product warranty
|
|
Connected equipment
insurance (USA and Canada Only):
|
$250,000 connected equipment
insurance (USA and Canada only)
|
|
SPECIAL
FEATURES |
|
EPO port:
|
Supports EPO (emergency power off)
via 73-0901 cabling
|
|
Cold Start:
|
Yes, inverter can be "cold started"
to enable temporary AC output during
a power failure
|
|
Appearance:
|
Attractive all-black tower housing
|
|
BATTERY
PACK ACCESSORY (optional) |
|
Battery Pack Accessory
(optional):
|
BP36V13
|
|
|
|
|
 | |
 |
|