MCStel Logo for your business telephones and data systems needs

Phone:

800-247-1002

Fax:

609-859-1005

business telephones and data systems

Your Zone for Business Telephone, Voice & Data Solutions

 HOME
 About Us
 Contact Us
 Services
 Privacy Policy
 Store Policy
 Info Desk
 View Cart
pad
 Shop by Category
pad
   Do-it-yourself Systems
pad
   Business to Business
pad
   Music On Hold
pad
   Voice Over IP Hardware
pad
   Digital Wireless Phones
pad
   Headsets
pad
   Power Protection
pad
   Telephones Central
pad
   Networking Hardware
pad
   Survelliance Equipment
pad
 Shop by Brand
pad
   Aastra Products
pad
   Adtran
pad
   AT&T Products
pad
   Avaya
pad
   CISCO
pad
   Vertical Comdial
pad
   Command Products
pad
   Nortel Products
pad
   On Hold Plus
pad
   Panasonic Products
pad
   Polycom Conferencing
pad
   RCA Telephones
pad
   Telematrix Hospitality
pad
   Tripp Lite
pad
   Uniden
pad
   VTech
pad
 Info Desk
pad
   MCS Core Services
pad
   Contact MCSnetZone
pad
   Store Policy
pad
   Privacy Policy
pad
   About Us
pad
   Contact Us
pad
   Security
pad
   Shipping Info
pad
   Track your Order
pad
   Search
pad
   Site Map
pad
   Sites we Like
pad
   News
pad
 Catalog 2008
pad
   Catalog 2008
pad
pad
pad
[ Home > Shop by Brand > Tripp Lite > Tripp Lite SmartOnline Expandable UPS Systems > Tripp Lite Smart Online 1000VA Expandable 2U Rack/Tower UPS System SU1000RTXL2Ua ]

pad
Tripp Lite Smart Online 1000VA Expandable 2U Rack/Tower UPS System SU1000RTXL2Ua
Enlarge Image

pad

Tripp Lite Smart Online 1000VA Expandable 2U Rack/Tower UPS System SU1000RTXL2Ua



Availability: Usually ships the same business day.Tripp Lite Smart Online 1000VA Expandable 2U Rack/Tower UPS System SU1000RTXL2Ua
SU1000RTXL2Ua netZone Price: $659.00padSale price: $549.95

Qty.:  

New Page 5

DESCRIPTION

1000VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an installed depth of only 13.5 in. Expandable battery runtime with optional BP24V28-2U and BP24V70-3U external battery packs. Full-time sine wave 100, 110 or 120V +/-2% output. Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 138V. NEMA 5-15P input plug; NEMA 5-15R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot. HID-compliant USB interface enables full integration with built-in power management and auto shutdown features of Windows, Mac OS X and Linux. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two-bank PDU switching supports load shedding and remote reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs. Dataline surge suppression for dialup, DSL or network Ethernet connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories included; 2-9USTAND tower kit and 2POSTRMKITWM two post rack & wallmount accessories available. Field replaceable, hot-swappable internal batteries and external battery packs. Attractive all-black color scheme. 2-year warranty and $250,000 connected equipment insurance; extended warranty and service contracts available.

  KEY BUYING POINTS

SmartOnline high performance UPS system is ideal for critical voice, data, medical and industrial network applications

True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 100/110/120V (user selectable) under all usage conditions

Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time

Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types

Corrects line voltage conditions as low as 65V and as high as 138V back to selectable 100/110/120V (+/-2%) values

Standard internal battery set offers 18 minutes runtime at half load (400W) and 6 minutes at full load (800W)

Optional BP24V28-2U external battery pack increases runtime to 74 minutes at half load (400W) and 33 minutes at full load (800W / limit 1)

Optional BP24V70-3U external battery pack increases runtime to 192 minutes at half load (400W) and 90 minutes at full load (800W / multi-pack compatible)

Compact rackmount form factor installs using only 2 rack spaces (2U) with a maximum installed depth of only 13.5 inches

Ships with all mounting accessories for 4 post rackmount installation

Optional 2POSTRMKITWM enables 2 post rackmount or wallmount installation

Optional 2-9USTAND accessory enables small-footprint upright tower placement

Fault tolerant auto-bypass maintains continuous utility output to connected equipment, even in cases where the UPS suffers internal failure and requires maintenance

Network interfaces support simultaneous communications via built-in USB, DB9 serial and SNMPWEBCARD slot

HID compliant USB interface enables full integration with built-in power management and auto shutdown features of Windows, Mac OS X and Linux.

Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP

UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter sutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment and UPS line to battery power voltage setpoints

Built-in Emergency Power Off (EPO) interface with cable

NEMA 5-15P input plug / NEMA 5-15R output receptacles

Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual devices (each load bank consists of two outlets)

Front panel LEDs offer current monitoring and battery charge level information

UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection of internal batteries by user required

Supports 2 post rackmount installation with optional 2POSTRMKITWM accessory

Single line TEL/DSL or network ethernet line surge suppression

2 year manufacturer's product warranty, $250,000 ULtimate Lifetime Insurance

  TYPICAL APPLICATIONS

Ideal for protection of critical 120v equipment in server rooms, internetworking closets and telecommunications systems in rackmount or tower applications. Common applications include corporate or departmental servers, workstations, hubs, routers, bridges, CAD/CAM workstations, concentrators, IP telephony and traditional PBX switching systems.

  OPTIONS & ACCESSORIES

External battery pack: BP24V28-2U, BP24V70-3U

SNMP accessories: SNMPWEBCARD, ENVIROSENSE

Dataline protectors: DNET1, DTEL2, DCATV

Circuit Tester: CT120

Rack enclosures: Rack Systems

Power distribution: PDU1215, PS7224

Two Post Rackmount/Wallmount Kit: 2POSTRMKITWM

Tower Stands: 2-9USTAND

Extended warranties: 3 Year WEXT3-500-1500, 5 Year WEXT5-500-1500

  PACKAGE INCLUDES

SU1000RTXL2Ua Online Double-Conversion UPS System

PowerAlert Software and cabling

Mounting hardware for 4 post rack enclosures

Instruction manual with warranty information

New Page 5

COMPLETE SPECIFICATIONS
SYSTEM OVERVIEW
System overview:
Online, double conversion 2U rack/tower UPS
Voltage compatibility:
120V AC (100/110/120V)
Frequency compatibility:
50/60 Hz compatible (auto-sensing)
OUTPUT
Output volt amp capacity (VA):
1000
Output watt capacity (watts):
800
Output nominal voltage:
120V AC (100/110/120V)
Output voltage regulation:
Maintains full-time sine wave output within 2% of selected nominal, less than 3% total harmonic distortion (linear load) / 6% total harmonic distortion (computer load)
Output frequency regulation:
Regulates line frequency to 50/60Hz +/- 0.05Hz
Outlet quantity / type:
6 NEMA 5-15R
Customized load management receptacles:
2 controllable load banks support automated load shedding and remote reboot on demand of locked network devices.
Overload protection:
15A input breaker
INPUT
Maximum input amps:
8.6A
Input connection type:
NEMA 5-15P
Input cord length:
6 ft. 14 gauge
Recommended electrical service:
15A 120V
BATTERY
Full load runtime:
6 minutes with internal batteries (800 watts)
Half load runtime:
18 minutes with internal batteries (400 watts)
Expandable battery runtime:
Supports extended runtime with optional external battery pack BP24V28-2U (limit 1) and BP24V70-3U (multi-pack compatible)
DC system voltage:
24VDC
Typical battery lifespan:
3-6 years, depending on usage
Battery recharge rate:
Less than 6 hours to 80%
Replacement Battery Cartridge:
RBC92-2U
VOLTAGE REGULATION
Voltage regulation description:
On-line, double-conversion power conditioning maintains output within 2% of 100/110/120 volts at all times
Overvoltage correction:
Maintains output of selected nominal +/-2% during overvoltages to 138V AC
Brownout correction:
Maintains output of selected nominal +/-2% during undervoltages to 65V AC (at loads greater than 70% undervoltage correction extends to 80V)
LEDS ALARMS & SWITCHES
Front panel LEDs:
LED STATUS DISPLAY: line power (green), online (green), bypass (yellow), on battery (green), overload (red), battery low (yellow) - 4 LED LOAD / BATTERY LEVEL DISPLAY (100%, 75%, 50%, 25%)
Alarms:
Multi-function audible alarm with distinctive ring patterns offer notification of backup operation (2 seconds on / 0.5 seconds off), low battery warning (1.25 seconds on / 0.5 seconds off), overload (sounds continuously), UPS fault (4.2 seconds on / 1 second off), input voltage out of frequency (2.1 seconds on / 0.14 seconds off) and high input voltage (2.1 seconds on 0.07 seconds off)
Switches:
Includes power off/on switch to enable system turn on (press ON switch), UPS battery test (press ON switch during normal AC operation), buzzer silence (press ON switch during battery operation) and OFF (press OFF switch) - all switch functions require that the switch be pressed and held for longer than 2 seconds, but less than 4 seconds
SURGE / NOISE SUPPRESSION
AC surge suppression:
480 joules
AC suppression response time:
Instantaneous
Dataline suppression:
Set of 8 wire RJ style interface jacks offer surge suppression for network ethernet or TEL/DSL connection. Pins 1,2,3 and 6 offer ethernet protection starting at 7.5V and the center two wires, pins 4 & 5, offer TEL/DSL line suppression starting at 260V
EMI / RFI AC noise suppression:
Yes
PHYSICAL
Shipping weight (lbs):
29
Shipping weight (kg):
13.2
Unit weight (lbs):
41
Unit weight (kg):
18.6
Unit Dimensions (HWD/in):
3.5 x 17.5 x 13.5
Unit Dimensions (HWD/cm):
8.9 x 44.5 x 34.3
Shipping Dimensions (HWD/in):
9.5 x 20 x 24
Shipping Dimensions (HWD/cm):
24.1 x 50.8 x 61
Material of construction:
Steel
Form factors supported:
Rack/Tower (2U)
Cooling method:
Built-in cooling fan
Battery Access:
User replaceable, hot swap battery replacement supported via front access panel
ENVIRONMENTAL
Operating Temperature:
+32 to +104 degrees Fahrenheit
0 to +40 degrees Celsius
Storage Temperature:
+5 to +122 degrees Fahrenheit
-15 to +50 degrees Celsius
Relative Humidity:
0 to 95%, non-condensing
COMMUNICATIONS
Network monitoring port:
Includes USB and DB9 serial ports. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID compliant USB interface enables full integration with built-in power management and auto shutdown features of Windows, Mac OS X and Linux
Software and cabling included:
Yes, includes PowerAlert software CD-ROM and complete cabling
SNMP compatibility:
Yes, includes slot for optional SNMPWEBCARD accessory (#SNMPWEBCARD)
WatchDog compatibility:
Yes, compatible with Tripp Lite's Watchdog system service to restore operation to locked equipment through soft reboot of application / OS or hard power off/on reboot of connected equipment—ideal for unattended kiosk applications
LINE / BATTERY TRANSFER
Transfer time from line power to battery mode:
Zero, online UPS continuously converts incoming AC to DC, then back to AC. When commercial power is interrupted, UPS maintains continuous output from battery reserves with absolutely no disruption in output AC power.
Low voltage transfer to battery power:
Maintains continuous operation during undervoltages as low as 65V (80V at load levels over 70%). Below this switchover point, output is supported from battery derived AC power.
High voltage transfer to battery power:
Maintains continuous operation without using battery power during overvoltages to 138V. Above this point, output is supported from battery derived AC power.
CERTIFICATIONS
Certifications:
Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), NOM (Mexico), Class B (EMI), FCC Part 68 / Industry Canada (Telecommunications)
WARRANTY
Optional coverage:
3-5 year warranties, plus next day and on-site warranty coverage available for select opportunities. Contact Tripp Lite for additional information.
Product warranty:
2 year product warranty
Connected equipment insurance (USA and Canada Only):
$250,000 connected equipment insurance (USA and Canada only)
SPECIAL FEATURES
EPO port:
Supports "Emergency Power Off" via dedicated built-in EPO jack
Cold Start:
Yes, inverter can be "cold started" to enable temporary AC output during a power failure
Appearance:
Attractive black steel rackmount housing
BATTERY PACK ACCESSORY (optional)
Battery Pack Accessory (optional):
BP24V28-2U, BP24V70-3U (optional)




 padShop by Category   Shop by Brand   Info Desk   Catalog 2008   Site Mappad