 Tripp Lite Smart Online 1000VA Expandable 2U Rack/Tower UPS System SU1000RTXL2Ua
Availability: Usually ships the same business day.Tripp Lite Smart Online 1000VA Expandable 2U Rack/Tower UPS System SU1000RTXL2Ua SU1000RTXL2Ua netZone Price: $659.00 Sale price: $549.95
 Qty.:

New Page 5
DESCRIPTION 1000VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an installed depth of only 13.5 in. Expandable battery runtime with optional BP24V28-2U and BP24V70-3U external battery packs. Full-time sine wave 100, 110 or 120V +/-2% output. Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 138V. NEMA 5-15P input plug; NEMA 5-15R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot. HID-compliant USB interface enables full integration with built-in power management and auto shutdown features of Windows, Mac OS X and Linux. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two-bank PDU switching supports load shedding and remote reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs. Dataline surge suppression for dialup, DSL or network Ethernet connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories included; 2-9USTAND tower kit and 2POSTRMKITWM two post rack & wallmount accessories available. Field replaceable, hot-swappable internal batteries and external battery packs. Attractive all-black color scheme. 2-year warranty and $250,000 connected equipment insurance; extended warranty and service contracts available.
KEY BUYING POINTS SmartOnline high performance UPS system is ideal for critical voice, data, medical and industrial network applications
True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 100/110/120V (user selectable) under all usage conditions
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types
Corrects line voltage conditions as low as 65V and as high as 138V back to selectable 100/110/120V (+/-2%) values
Standard internal battery set offers 18 minutes runtime at half load (400W) and 6 minutes at full load (800W)
Optional BP24V28-2U external battery pack increases runtime to 74 minutes at half load (400W) and 33 minutes at full load (800W / limit 1)
Optional BP24V70-3U external battery pack increases runtime to 192 minutes at half load (400W) and 90 minutes at full load (800W / multi-pack compatible)
Compact rackmount form factor installs using only 2 rack spaces (2U) with a maximum installed depth of only 13.5 inches
Ships with all mounting accessories for 4 post rackmount installation
Optional 2POSTRMKITWM enables 2 post rackmount or wallmount installation
Optional 2-9USTAND accessory enables small-footprint upright tower placement
Fault tolerant auto-bypass maintains continuous utility output to connected equipment, even in cases where the UPS suffers internal failure and requires maintenance
Network interfaces support simultaneous communications via built-in USB, DB9 serial and SNMPWEBCARD slot
HID compliant USB interface enables full integration with built-in power management and auto shutdown features of Windows, Mac OS X and Linux.
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP
UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter sutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment and UPS line to battery power voltage setpoints
Built-in Emergency Power Off (EPO) interface with cable
NEMA 5-15P input plug / NEMA 5-15R output receptacles
Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual devices (each load bank consists of two outlets)
Front panel LEDs offer current monitoring and battery charge level information
UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection of internal batteries by user required
Supports 2 post rackmount installation with optional 2POSTRMKITWM accessory
Single line TEL/DSL or network ethernet line surge suppression
2 year manufacturer's product warranty, $250,000 ULtimate Lifetime Insurance
TYPICAL APPLICATIONS Ideal for protection of critical 120v equipment in server rooms, internetworking closets and telecommunications systems in rackmount or tower applications. Common applications include corporate or departmental servers, workstations, hubs, routers, bridges, CAD/CAM workstations, concentrators, IP telephony and traditional PBX switching systems.
OPTIONS & ACCESSORIES External battery pack: BP24V28-2U, BP24V70-3U
SNMP accessories: SNMPWEBCARD, ENVIROSENSE
Dataline protectors: DNET1, DTEL2, DCATV
Circuit Tester: CT120
Rack enclosures: Rack Systems
Power distribution: PDU1215, PS7224
Two Post Rackmount/Wallmount Kit: 2POSTRMKITWM
Tower Stands: 2-9USTAND
Extended warranties: 3 Year WEXT3-500-1500, 5 Year WEXT5-500-1500
PACKAGE INCLUDES SU1000RTXL2Ua Online Double-Conversion UPS System
PowerAlert Software and cabling
Mounting hardware for 4 post rack enclosures
Instruction manual with warranty information
New Page 5
|
SYSTEM
OVERVIEW |
|
System overview:
|
Online, double conversion 2U
rack/tower UPS
|
|
Voltage compatibility:
|
120V AC (100/110/120V)
|
|
Frequency compatibility:
|
50/60 Hz compatible (auto-sensing)
|
|
OUTPUT |
|
Output volt amp capacity
(VA):
|
1000
|
|
Output watt capacity
(watts):
|
800
|
|
Output nominal voltage:
|
120V AC (100/110/120V)
|
|
Output voltage regulation:
|
Maintains full-time sine wave output
within 2% of selected nominal, less
than 3% total harmonic distortion
(linear load) / 6% total harmonic
distortion (computer load)
|
|
Output frequency regulation:
|
Regulates line frequency to 50/60Hz
+/- 0.05Hz
|
|
Outlet quantity / type:
|
6 NEMA 5-15R
|
|
Customized load management
receptacles:
|
2 controllable load banks support
automated load shedding and remote
reboot on demand of locked network
devices.
|
|
Overload protection:
|
15A input breaker
|
|
INPUT |
|
Maximum input amps:
|
8.6A
|
|
Input connection type:
|
NEMA 5-15P
|
|
Input cord length:
|
6 ft. 14 gauge
|
|
Recommended electrical
service:
|
15A 120V
|
|
BATTERY |
|
Full load runtime:
|
6 minutes with internal batteries
(800 watts)
|
|
Half load runtime:
|
18 minutes with internal batteries
(400 watts)
|
|
Expandable battery runtime:
|
Supports extended runtime with
optional external battery pack
BP24V28-2U (limit 1) and BP24V70-3U
(multi-pack compatible)
|
|
DC system voltage:
|
24VDC
|
|
Typical battery lifespan:
|
3-6 years, depending on usage
|
|
Battery recharge rate:
|
Less than 6 hours to 80%
|
|
Replacement Battery
Cartridge:
|
RBC92-2U
|
|
VOLTAGE
REGULATION |
|
Voltage regulation
description:
|
On-line, double-conversion power
conditioning maintains output within
2% of 100/110/120 volts at all times
|
|
Overvoltage correction:
|
Maintains output of selected nominal
+/-2% during overvoltages to 138V AC
|
|
Brownout correction:
|
Maintains output of selected nominal
+/-2% during undervoltages to 65V AC
(at loads greater than 70%
undervoltage correction extends to
80V)
|
|
LEDS
ALARMS & SWITCHES |
|
Front panel LEDs:
|
LED STATUS DISPLAY: line power
(green), online (green), bypass
(yellow), on battery (green),
overload (red), battery low (yellow)
- 4 LED LOAD / BATTERY LEVEL DISPLAY
(100%, 75%, 50%, 25%)
|
|
Alarms:
|
Multi-function audible alarm with
distinctive ring patterns offer
notification of backup operation (2
seconds on / 0.5 seconds off), low
battery warning (1.25 seconds on /
0.5 seconds off), overload (sounds
continuously), UPS fault (4.2
seconds on / 1 second off), input
voltage out of frequency (2.1
seconds on / 0.14 seconds off) and
high input voltage (2.1 seconds on
0.07 seconds off)
|
|
Switches:
|
Includes power off/on switch to
enable system turn on (press ON
switch), UPS battery test (press ON
switch during normal AC operation),
buzzer silence (press ON switch
during battery operation) and OFF
(press OFF switch) - all switch
functions require that the switch be
pressed and held for longer than 2
seconds, but less than 4 seconds
|
|
SURGE /
NOISE SUPPRESSION |
|
AC surge suppression:
|
480 joules
|
|
AC suppression response
time:
|
Instantaneous
|
|
Dataline suppression:
|
Set of 8 wire RJ style interface
jacks offer surge suppression for
network ethernet or TEL/DSL
connection. Pins 1,2,3 and 6 offer
ethernet protection starting at 7.5V
and the center two wires, pins 4 &
5, offer TEL/DSL line suppression
starting at 260V
|
|
EMI / RFI AC noise
suppression:
|
Yes
|
|
PHYSICAL |
|
Shipping weight (lbs):
|
29
|
|
Shipping weight (kg):
|
13.2
|
|
Unit weight (lbs):
|
41
|
|
Unit weight (kg):
|
18.6
|
|
Unit Dimensions (HWD/in):
|
3.5 x 17.5 x 13.5
|
|
Unit Dimensions (HWD/cm):
|
8.9 x 44.5 x 34.3
|
|
Shipping Dimensions
(HWD/in):
|
9.5 x 20 x 24
|
|
Shipping Dimensions
(HWD/cm):
|
24.1 x 50.8 x 61
|
|
Material of construction:
|
Steel
|
|
Form factors supported:
|
Rack/Tower (2U)
|
|
Cooling method:
|
Built-in cooling fan
|
|
Battery Access:
|
User replaceable, hot swap battery
replacement supported via front
access panel
|
|
ENVIRONMENTAL |
|
Operating Temperature:
|
+32 to +104 degrees Fahrenheit
0 to +40 degrees Celsius
|
|
Storage Temperature:
|
+5 to +122 degrees Fahrenheit
-15 to +50 degrees Celsius
|
|
Relative Humidity:
|
0 to 95%, non-condensing
|
|
COMMUNICATIONS |
|
Network monitoring port:
|
Includes USB and DB9 serial ports.
Built-in DB9 port offers both
enhanced RS-232 enabled monitoring
data, plus contact closure
monitoring ability. HID compliant
USB interface enables full
integration with built-in power
management and auto shutdown
features of Windows, Mac OS X and
Linux
|
|
Software and cabling
included:
|
Yes, includes PowerAlert software
CD-ROM and complete cabling
|
|
SNMP compatibility:
|
Yes, includes slot for optional
SNMPWEBCARD accessory (#SNMPWEBCARD)
|
|
WatchDog compatibility:
|
Yes, compatible with Tripp Lite's
Watchdog system service to restore
operation to locked equipment
through soft reboot of application /
OS or hard power off/on reboot of
connected equipment—ideal for
unattended kiosk applications
|
|
LINE /
BATTERY TRANSFER |
|
Transfer time from line
power to battery mode:
|
Zero, online UPS continuously
converts incoming AC to DC, then
back to AC. When commercial power is
interrupted, UPS maintains
continuous output from battery
reserves with absolutely no
disruption in output AC power.
|
|
Low voltage transfer to
battery power:
|
Maintains continuous operation
during undervoltages as low as 65V
(80V at load levels over 70%). Below
this switchover point, output is
supported from battery derived AC
power.
|
|
High voltage transfer to
battery power:
|
Maintains continuous operation
without using battery power during
overvoltages to 138V. Above this
point, output is supported from
battery derived AC power.
|
|
CERTIFICATIONS |
|
Certifications:
|
Tested to UL1778 (USA), CSA C22.2
No. 107.3 (Canada), NOM (Mexico),
Class B (EMI), FCC Part 68 /
Industry Canada (Telecommunications)
|
|
WARRANTY |
|
Optional coverage:
|
3-5 year warranties, plus next day
and on-site warranty coverage
available for select opportunities.
Contact Tripp Lite for additional
information.
|
|
Product warranty:
|
2 year product warranty
|
|
Connected equipment
insurance (USA and Canada Only):
|
$250,000 connected equipment
insurance (USA and Canada only)
|
|
SPECIAL
FEATURES |
|
EPO port:
|
Supports "Emergency Power Off" via
dedicated built-in EPO jack
|
|
Cold Start:
|
Yes, inverter can be "cold started"
to enable temporary AC output during
a power failure
|
|
Appearance:
|
Attractive black steel rackmount
housing
|
|
BATTERY
PACK ACCESSORY (optional) |
|
Battery Pack Accessory
(optional):
|
BP24V28-2U, BP24V70-3U (optional)
|
|
|
|
|
|