SYSTEM
OVERVIEW |
|
Voltage compatibility:
|
120VAC
|
|
Frequency compatibility:
|
60 Hz
|
|
OUTPUT |
|
Output volt amp capacity
(VA):
|
550
|
|
Output watt capacity
(watts):
|
300
|
|
Output nominal voltage:
|
120V
|
|
Output voltage regulation:
|
LINE MODE: Passes sine wave line
voltage from 100-138V to connected
equipment unchanged BATTERY MODE:
PWM sine wave output 115V +/-5%
|
|
Output frequency regulation:
|
LINE MODE: Passes line frequency of
60Hz +/-10% BATTERY MODE: Inverter
output regulated to 60zHz +/-0.5Hz
|
|
Outlet quantity / type:
|
8 NEMA 5-15R
|
|
INPUT |
|
Maximum input amps:
|
12A
|
|
Input connection type:
|
NEMA 5-15R
|
|
Input cord length:
|
6 ft., 16 gauge
|
|
Recommended electrical
service:
|
15A, 120VAC
|
|
BATTERY |
|
Full load runtime:
|
3 minutes (550VA)
|
|
Half load runtime:
|
10 minutes (275VA)
|
|
DC system voltage:
|
12VDC
|
|
Typical battery lifespan:
|
3-6 years, depending on usage
|
|
Battery recharge rate:
|
2-4 hours to 90%
|
|
LEDS
ALARMS & SWITCHES |
|
Front panel LEDs:
|
2 LEDs indicate line power, battery
power status
|
|
Alarms:
|
Audible alarm indicates battery
backup operation
|
|
Switches:
|
Power on/off switch
|
|
SURGE /
NOISE SUPPRESSION |
|
AC surge suppression:
|
380 joules
|
|
AC suppression response
time:
|
Instantaneous
|
|
Dataline suppression:
|
Tel/DSL
|
|
EMI / RFI AC noise
suppression:
|
Yes
|
|
PHYSICAL |
|
Shipping weight (lbs):
|
14.25
|
|
Shipping weight (kg):
|
6.5
|
|
Unit weight (lbs):
|
10.95
|
|
Unit weight (kg):
|
5
|
|
Unit Dimensions (HWD/in):
|
3.5 x 11.25 x 6
|
|
Unit Dimensions (HWD/cm):
|
8.3 x 28.6 x 15.2
|
|
Shipping Dimensions
(HWD/in):
|
10.75 x 14 x 18.25
|
|
Shipping Dimensions
(HWD/cm):
|
27.3 x 35.6 x 46.4
|
|
Material of construction:
|
ABS
|
|
Form factors supported:
|
Ultra-compact, wall-mountable
|
|
Battery Access:
|
Via battery access panel
|
|
ENVIRONMENTAL |
|
Operating Temperature:
|
+32 to +104 degrees Fahrenheit, 0 to
+40 degrees Celsius
|
|
Storage Temperature:
|
+5 to +122 degrees Fahrenheit, -15
to +50 degrees Celsius
|
|
Relative Humidity:
|
0 to 95%, non-condensing
|
|
COMMUNICATIONS |
|
Network monitoring port:
|
DB9
|
|
Software and cabling
included:
|
Includes DB9 serial cable,
PowerAlert software available via
free download from
http://www.tripplite.com
|
|
LINE /
BATTERY TRANSFER |
|
Transfer time from line
power to battery mode:
|
2-4 milliseconds
|
|
Low voltage transfer to
battery power:
|
Switches to battery power as line
voltage drops to 99V. Resets back to
line power as line voltage increases
to 104V or higher
|
|
High voltage transfer to
battery power:
|
Switches to battery power as line
voltage increases to 138V or higher.
Resets to line power as line voltage
drops to 135V or lower
|
|
CERTIFICATIONS |
|
Certifications:
|
Tested to UL1778 (USA), CSA C22.2
No. 107.3 (Canada), Class B
(Emissions), NOM (Mexico), FCC Part
68 / Industry Canada
(telecommunications)
|
|
WARRANTY |
|
Product warranty:
|
2 years
|
|
Connected equipment
insurance (USA and Canada Only):
|
$100,000 connected equipment
insurance (USA and Canada only)
|
|
SPECIAL
FEATURES |
|
Cold Start:
|
Inverter can be "cold started" to
enable temporary AC output during a
power failure
|
|
Appearance:
|
Attractive black ultra-compact
housing
|