| SYSTEM OVERVIEW |
System overview: |
Line interactive tower UPS protects internetworking and telecommunications equipment from blackouts, brownouts, overvoltages, surges and line noise. Maintains AC output during blackouts and continuously corrects brownouts and overvoltages from 87 to 140 volts back to normal 120V levels. Supports external battery packs for extended runtime. Includes 3 built-in DB9 serial ports, PowerAlert UPS monitoring software and two customized load management receptacles. |
Voltage compatibility: |
120V AC |
Frequency compatibility: |
60 Hz |
| OUTPUT |
Output volt amp capacity (VA): |
2200 |
Output watt capacity (watts): |
1700 |
Output nominal voltage: |
120V AC |
Output voltage regulation: |
LINE MODE: Sine wave line voltage 120V (-13% / +5%) BATTERY MODE: PWM sine wave output 120V +/-5% |
Output frequency regulation: |
LINE MODE: Passes line frequency of 60Hz +/-10% BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz |
Outlet quantity / type: |
6 NEMA 5-15R |
Customized load management receptacles: |
3 serial ports |
Overload protection: |
Via 20A input breaker |
| INPUT |
Maximum input amps: |
15A, 1770 watts |
Input connection type: |
NEMA 5-15P |
Input cord length: |
8 ft., 12 gauge |
Recommended electrical service: |
20A 120V |
| BATTERY |
Full load runtime: |
11 minutes (2200VA) |
Half load runtime: |
27 minutes (1100VA) |
Expandable battery runtime: |
Supports extended runtime with optional BP24V33 external battery pack (multi-pack compatible). Capacity de-rates to 1600VA / 1280 watts with 1 external BP and 1250VA / 800 watts with 2 external BPs |
DC system voltage: |
24 V DC |
Typical battery lifespan: |
3-6 years, depending on usage |
Battery recharge rate: |
2-4 hours to 90% |
| VOLTAGE REGULATION |
Voltage regulation description: |
Line interactive UPS offers 2 boost levels of brownout correction and a single level of overvoltage adjustment to maintain usable, computer grade output without consuming battery power. |
Overvoltage correction: |
Input voltages between 127 and 140V AC are reduced by 12% |
Direct pass through: |
Input voltages between 110 and 127V AC are passed through unchanged |
Brownout correction: |
Input voltages between 95 and 105V AC are boosted by 10% |
Severe brownout correction: |
Input voltages between 87 and 94V AC are boosted by 22% |
| LEDS ALARMS & SWITCHES |
Front panel LEDs: |
Includes 5 front panel LEDs to indicate BATTERY CHARGE LEVEL, AC LINE POWER STATUS, VOLTAGE REGULATION STATUS, UPS LOAD LEVEL and BATTERY LOW / REPLACE information |
Alarms: |
Audible alarm with 15 second delay sounds to indicate loss of utility power. Alarm can be silenced by pressing front panel alarm cancel button. Once silenced, alarm will re-sound when approximately 2 minutes runtime remain. |
Switches: |
Includes 2 front panel switches — one on/standby power switch and one dual function "alarm cancel" / "self test" button, plus 1 rear panel system enable switch |
| SURGE / NOISE SUPPRESSION |
AC surge suppression: |
480 joules |
AC suppression response time: |
Instantaneous |
EMI / RFI AC noise suppression: |
Yes |
| PHYSICAL |
Shipping weight (lbs): |
87 |
Shipping weight (kg): |
39.5 |
Unit weight (lbs): |
80 |
Unit weight (kg): |
36.3 |
Unit Dimensions (HWD/in): |
17 x 9 x 12.5 |
Unit Dimensions (HWD/cm): |
41.9 x 22.9 x 31.1 |
Shipping Dimensions (HWD/in): |
22.25 x 12.75 x 16.5 |
Shipping Dimensions (HWD/cm): |
57.2 x 32.4 x 42 |
Material of construction: |
Polycarbonate |
Form factors supported: |
Tower |
Cooling method: |
Convection |
| ENVIRONMENTAL |
Operating Temperature: |
+32 to +104 degrees Fahrenheit 0 to +40 degrees Celsius |
Storage Temperature: |
+5 to +122 degrees Fahrenheit -15 to +50 degrees Celsius |
Relative Humidity: |
0 to 95%, non-condensing |
Line mode BTU/hr. (Max.): |
148.2 |
Battery mode BTU/hr. (Max.): |
502.6 |
| COMMUNICATIONS |
Network monitoring port: |
Includes 3 built-in DB9 monitoring ports, 1 enabled with RS-232 data communications and 2 with standard contact closure communications. All interfaces support on battery, low battery and power restored messaging. RS-232 enabled port adds data regarding AC line voltage, DC battery voltage, load percentage, battery charge current, battery capacity, internal UPS temperature and line frequency status messaging. Supports individual reboot of selected items connected to load management receptacles and load shedding to increase battery runtime for the most critical loads. |
Software and cabling included: |
Includes PowerAlert UPS monitoring software for all common network and standalone operating systems. |
| LINE / BATTERY TRANSFER |
Transfer time from line power to battery mode: |
2-4 milliseconds |
Low voltage transfer to battery power: |
Switches to battery power as line voltage decreases to 87 volts or less |
High voltage transfer to battery power: |
Switches to battery power as line voltage increases to 140 volts or higher. |
| CERTIFICATIONS |
Certifications: |
UL1778 (USA), cUL (Canada), FCC Class A (emissions), NOM (Mexico) |
| WARRANTY |
Optional coverage: |
3-5 year warranties, plus next day and on-site warranty coverage available for select opportunities. Contact Tripp Lite for additional information |
Product warranty: |
2 year product warranty |
Connected equipment insurance (USA and Canada Only): |
$250,000 connected equipment insurance (USA / Canada only) |
| SPECIAL FEATURES |
Appearance: |
Attractive gray tower UPS |
| BATTERY PACK ACCESSORY (optional) |
Battery Pack Accessory (optional): |
BP24V33 |